###
气象:2016,42(11):1387-1394
本文二维码信息
码上扫一扫!
河南电网“污闪”故障的综合气象因素分析
(1.中国气象局公共气象服务中心, 北京 100081;2.国家电网河南省电力公司电力科学研究院,郑州 450052)
Analysis of the Integrated Meteorological Factors of Power Equipment Pollution Flashover in Henan
摘要
图/表
参考文献
相似文献
本文已被:浏览 1102次   下载 1590
投稿时间:2016-03-01    修订日期:2016-07-17
中文摘要: 综合考虑河南省范围内电网污闪故障的时空分布特征及地理地貌特征,利用河南省电网污闪故障数据及地面气象观测数据,研究首先确定了与该地区电网污闪故障密切相关的积污持续时间、近地层逆温、相对湿度、风速风向等环境气象特征参数,然后采用时空匹配、统计阈值分析和综合气象指标调整优化等手段,对各特征参数的综合阈值进行了初步评定,最终建立了河南省电网污闪故障的可定量化综合气象分析指标及对应气象条件:高湿、弱风、前期少雨、近地面大气层结稳定。该指标较好地拟合了气象环境条件与污闪故障之间的关系,检验结果显示指标无漏报,且空报率低于10%;基于该指标计算的多年平均条件下,河南地区污闪故障多发生在冬季,且河南东北部为电网污闪故障高发区。研究成果为河南地区的电网污闪故障防御提供了技术支持。
Abstract:According to the spetio temporal distribution characteristics of the power equipment pollution flashover and the geographic features in Henan, duration of the contamination, temperature inversion near the ground surface, relative humidity and wind are firstly identified as import contributions to pollution flashover disaster. Then the composite thresholds of these factors are respectively assessed using the methods of spatio temporal matching, statistical analysis of threshold and model based on the flashover hazard data and meteorological observations. The comprehensive meteorological model for pollution flashover established here considers well the atmospheric conditions that breed the disaster, including high humidity, weak wind, less rain in the early period and stable atmospheric stratification near the surface. The model established here fits the relationship between the meteorological environmental conditions and the pollution flashover events well. The validation results indicate that the model can capture the disaster events with the false alarm rate less than 10%. The spatio temporal characteristics of the annual mean power flashover events calculated from the 30 year historical observations show high frequency over the northeast of Henan during wintertime. Thus, the findings in this paper would provide a scientific support for the early warning of power equipment pollution flashover in this region.
文章编号:     中图分类号:    文献标志码:
基金项目:国家电网公司重大基础前瞻科技项目(SG20141187)资助
引用文本:
常蕊,周宁,王欣雯,郭鹏,宋丽莉,梁允,2016.河南电网“污闪”故障的综合气象因素分析[J].气象,42(11):1387-1394.
CHANG Rui,ZHOU Ning,WANG Xinwen,GUO Peng,SONG Lili,LIANG Yun,2016.Analysis of the Integrated Meteorological Factors of Power Equipment Pollution Flashover in Henan[J].Meteor Mon,42(11):1387-1394.