ISSN 1000-0526
CN 11-2282/P
Analysis and Processing of the Transmitter Power Failure in CINRAD/SA
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The transmitter is an important part in CINRAD/SA radar. Because of its comp lex structure and running in the state of uninterrupted high voltage, a highest failurerate occurs among several extensions of radar system. Generally, th e rad ar system will be forced to halt once this fatal failure occurred. Based on an a b normal CINRAD/SA radar transmitter power decline, we find out that the failure lie s in the highfrequency pulse generator, which makes the pulse width depressed. And also, some maintenance methods are summed up here, from which the rad ar maintenance professional could take as reference.

    Reference
    Related
    Cited by
Get Citation
分享
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:April 13,2008
  • Revised:August 07,2009
  • Adopted:
  • Online:
  • Published:

WeChat

Mobile website