Errors Analysis of Aerodynamic Method in Turbulent Flux Calculation
Article
Figures
Metrics
Preview PDF
Reference
Related
Cited by
Materials
Abstract:
By using an alternative method the relative errors are examined of sensible heat and latent heat flux computed from the aerodynamic method. The results show that the relative errors of sensible heat and latent heat rapidly increased as u2.0<2.0m·s-1 and-△e<0.5hPa. The employing of this method is limited in the environment of tiny wind and low humidity.