###
气象:2023,49(10):1157-1170
←前一篇   |   后一篇→
本文二维码信息
码上扫一扫!
两种雨滴谱仪观测对比及对雷达降水估测精度影响研究
陈超,刘黎平,罗聪,刘显通,张阿思
(广东省气象台,广州 510640; 中国气象科学研究院灾害天气国家重点实验室,北京 100081; 中国气象局广州热带海洋气象研究所,广州 510640)
Comparison of Two Kinds of Disdrometers and Their Influence on the Accuracy of Radar Quantitative Precipitation Estimation
CHEN Chao,LIU Liping,LUO Cong,LIU Xiantong,ZHANG Asi
(Guangdong Meteorological Observatory, Guangzhou 510640; State Key Laboratory of Severe Weather, Chinese Academy of Meteorological Sciences, Beijing 100081; Institute of Tropical and Marine Meteorology, CMA, Guangzhou 510640)
摘要
图/表
参考文献
相似文献
本文已被:浏览 88次   下载 570
投稿时间:2022-05-09    修订日期:2023-07-18
中文摘要: 利用广东龙门、新丰和佛冈布设的二维视频雨滴谱仪(2D-video-disdrometer,2DVD)和HY-P1000激光雨滴谱仪观测资料,分析了相同地点和相同时间两类雨滴谱仪降水滴谱观测和降水反演精度的差异。根据收集的2018年和2019年的雨滴谱观测数据,拟合了双偏振雷达定量降水估测基本关系式,并应用于S波段双偏振雷达(CINRAD/SAD)定量降水估测(quantitive precipitation estimation,QPE)优化组合方案中。结果表明:较HY-P1000雨滴谱仪而言,2DVD可观测到更多的1mm以下的小粒子降水,但观测到的大于3.5 mm的雨滴数明显少于HY-P1000雨滴谱仪;对比由2DVD和HY-P1000观测数据计算得到的双偏振参数与CINRAD-SAD 0.5°仰角观测得到的双偏振参数,发现参数间均存在一定的差别,其中差分反射率因子差别相对较大;此外,利用2DVD观测数据可整体提升双偏振雷达QPE精度,对中雨及以下量级精度提升尤为明显。
Abstract:A laser optical disdrometer (HY-P1000) and a two-dimensional video disdrometer (2DVD) were used to measure the raindrop size distribution (DSD) at the Longmen, Xinfeng and Fogang weather stations in Guangdong Province. Differences between the DSD measured by HY-P1000 and 2DVD and the accuracy of precipitation retrieval in the same place and same time were analyzed. The fundamental equations used for quantitative precipitation estimation (QPE) algorithm were fitted by the disdrometer data collected during 2018 and 2019, and then the optimization rainfall algorithm (HCA-QPE) based on the equations above was applied to Guangzhou S-band dual polarization weather radar to improve the accuracy of QPE in Guangdong. The results showed that the 2DVD is more sensitive to small rain drops (<1 mm) while the HY-P1000 can measure much more rain drops larger than 3.5 mm. The polarization parameters retrieved from two types of disdrometers are different from those observed by S-band dual-polarization radar at 0.5° elevation, and the difference of differential reflectivity was relatively large. What’s more, using 2DVD observation data can improve the QPE accuracy of S-band dual polarization radar, especially for light to moderate rainfall.
文章编号:     中图分类号:    文献标志码:
基金项目:国家自然科学基金项目(41975138)、广东省自然科学基金项目(2022A1515011814、2020A1515010602)、雷达应用及强对流短时临近预警技术创新团队(GRMCTD202002)、广东省气象局科学技术研究项目(GRMC2020Z03) 和灾害天气国家重点实验室开放课题(2020LASW-B02、2022LASW-B15)共同资助
引用文本:
陈超,刘黎平,罗聪,刘显通,张阿思,2023.两种雨滴谱仪观测对比及对雷达降水估测精度影响研究[J].气象,49(10):1157-1170.
CHEN Chao,LIU Liping,LUO Cong,LIU Xiantong,ZHANG Asi,2023.Comparison of Two Kinds of Disdrometers and Their Influence on the Accuracy of Radar Quantitative Precipitation Estimation[J].Meteor Mon,49(10):1157-1170.