本文已被:浏览 948次 下载 2364次
投稿时间:2006-12-09 修订日期:2007-07-19
投稿时间:2006-12-09 修订日期:2007-07-19
中文摘要: 轴角箱是CINRAD/SA雷达天伺系统中联系数字控制电路与机械电机的关键环节,它的故障造
成雷达系统报警不断,方位环节故障将导致终端产品出现蜘蛛网状回波,俯仰环节故障则导
致系统无法工作。为了降低轴角箱故障造成对雷达正常运行的影响,通过对广州雷达站前后
出现的5次同类故障的综合分析,总结得出问题多出现在轴角箱的激磁电压环节,原因是由
于天线罩温度高、湿度大,导致部分元器件出现性能退化。针对薄弱环节,采取相应的改进
措施之后,问题得以彻底解决。
中文关键词: CINRAD/SA雷达 轴角箱故障 改进
Abstract:The encoder is a key part of servo system in CINRAD/SA radar, which contacts dig
ital control unit with mechanism of the pedestal. While failure happens in azimu
th loop, it will cause ananeose echo in products, and while fault happens in ele
vation loop, it will cause INOP about radar system. Five faults about the encode
r were analyzed. It discovered that the faults mainly come from the magnetizatio
n voltage. When the temperature and humidity are too high in the antenna dome,
partial parts will be degenerated. The problem will be throughout resolved after
some measures are taken.
keywords: CINRAD/SA radar encoder fault improvement
文章编号: 中图分类号: 文献标志码:
基金项目:广州市科技攻关项目(06A13043333)资助
作者 | 单位 |
胡东明 | 广州中心气象台, 510080 |
刘强 | 北京敏视达雷达有限公司 |
程元慧 | 广东省气象局业务处 |
吴少峰 | 广州中心气象台, 510080 |
胡胜 | 广州中心气象台, 510080 |
杨朝辉 | 广东省阳江市气象局 |
引用文本:
胡东明,刘强,程元慧,吴少峰,胡胜,杨朝辉,2007.CINRAD/SA天线伺服系统轴角箱多次故障的分析[J].气象,33(10):114-117.
Hu Dongming,Liu Qiang,Cheng Yuanhui,Wu Shaofeng,Hu Sheng,Yang Zhaohui,2007.Analysis of the Multi fault in Conder of Servo about CINRAD/SA Radar[J].Meteor Mon,33(10):114-117.
胡东明,刘强,程元慧,吴少峰,胡胜,杨朝辉,2007.CINRAD/SA天线伺服系统轴角箱多次故障的分析[J].气象,33(10):114-117.
Hu Dongming,Liu Qiang,Cheng Yuanhui,Wu Shaofeng,Hu Sheng,Yang Zhaohui,2007.Analysis of the Multi fault in Conder of Servo about CINRAD/SA Radar[J].Meteor Mon,33(10):114-117.