本文已被:浏览 973次 下载 1425次
中文摘要: 利用2004年山东省自动气象站地温传感器校准资料,分析了校准结果超出计量性能要求的原因。结果表明:造成校准超差的直接原因是自然环境温度过高引起温度校准设备内的温度分布不均匀,间接原因是标准温度传感器与被校准温度传感器在温度槽内不恰当的安装。
中文关键词: 自动站,温度传感器,误差分析,校准方法
Abstract:Base on regulating data of the temperature sensor of AWS in 2004 in Shandong Province, the cause of the result beyond measure is analyzed. The results show that the asymmetry of temperature field in detection equipment is influenced by super temperature in natural environment, and the standard temperature sensor and the ones regulated are not installed appropriately in the temperature equipment.
文章编号: 中图分类号: 文献标志码:
基金项目:
作者 | 单位 |
罗淇 | 山东省气象技术装备中心,济南 250031 |
Author Name | Affiliation |
引用文本:
罗淇,2005.自然环境校准自动气象站地温传感器超差成因分析[J].气象,31(11):52-54.
,2005.Error Analysis of Regulating Temperature Sensor of AWS in Natural Environment[J].Meteor Mon,31(11):52-54.
罗淇,2005.自然环境校准自动气象站地温传感器超差成因分析[J].气象,31(11):52-54.
,2005.Error Analysis of Regulating Temperature Sensor of AWS in Natural Environment[J].Meteor Mon,31(11):52-54.