中文摘要: 由于自动气象站安装在野外以及微电子装置的脆弱性,很容易遭受雷电损害。通过深圳市中尺度自动气象站网防雷设计的实践,作者对自动气象站防雷技术问题进行了讨论,提出了一套自动气象站雷电防护方案。
中文关键词: 自动气象站,防雷技术,TVS
Abstract:Automatic meteorological station is easily struck by lightning as it is generally installed in open field and the digital circuit is fragile. After the designinig practice in the Shenzhen mesoscale automatic meteorological observatory network, some lightning protection methods for automatic meteorological station are discussed, and a complete solution is provided.
文章编号: 中图分类号: 文献标志码:
基金项目:
Author Name | Affiliation |
引用文本:
周新,钱肇淇,1999.自动气象站防雷技术探讨[J].气象,25(3):54-57.
,1999.The Technical Discussion on Lightning Protection for Automatic meteorological Station[J].Meteor Mon,25(3):54-57.
周新,钱肇淇,1999.自动气象站防雷技术探讨[J].气象,25(3):54-57.
,1999.The Technical Discussion on Lightning Protection for Automatic meteorological Station[J].Meteor Mon,25(3):54-57.